OpenPetro AI · Learning Tools

MICP to Reservoir Saturation–Height

Take one sample's mercury injection curve from the lab to the reservoir: rescale for interfacial tension and contact angle, convert to height above free water level, and read Sw at any height or height at any Sw.

Pc,res = Pc,lab · (σ cos θ)res / (σ cos θ)lab
h = Pc,res / (0.433 · Δρ)

Lab system

σIFT dyn/cm
θcontact angle deg
|σ cos θ|– dyn/cm

Reservoir system

σIFT dyn/cm
θcontact angle deg
|σ cos θ|– dyn/cm

Reservoir fluids

ρwbrine g/cm³
ρhoil g/cm³
Δρ · 0.433– psi/ft

Conversion

Pc,res / Pc,lab–
Lab psi per ft above FWL–
Entry Pd → height–
If the sample sits at height above FWL
ft
its water saturation is
–
If the sample's reservoir water saturation is
v/v
it sits above the FWL at
–

Reservoir saturation–height

Height above free water level against water saturation, after conversion. The dashed line marks the entry height (top of the 100% water zone, near the oil–water contact). Hover to read Pc,res.

Lab MICP curve

Air–mercury capillary pressure against wetting-phase saturation (1 − SHg). The right-hand scale-free reading in the tooltip gives the equivalent reservoir Pc and height.

Pore-throat size distribution

From the Washburn equation with the lab σ and θ: r = 2σ|cos θ|/Pc. Bars show the increment of mercury saturation per pressure step.

MICP data

Two columns per line: lab capillary pressure (psi) and mercury saturation SHg (fraction or %). A column of Sw instead of SHg is detected automatically. Data stay in your browser.

Sample data (synthetic): 04_micp_good_sandstone.csv (good sandstone) 04_micp_tight_sandstone.csv (tight sandstone) 04_micp_sw_percent.txt (Sw in %, tab-separated)

Converted table

Every measured point, carried from the lab to the reservoir.

Sensitivity of the two answers

How the answers move with the least certain inputs. Reservoir σ and θ, and the density contrast, usually matter most.

Method and assumptions