Sandstone with dispersed clay: convert total porosity and saturation to the effective system, then compare Timur, Tixier and Coates, check irreducible water on a Buckles plot, and calibrate to core.
Swe vs φe with lines of constant bulk volume water. Samples at irreducible saturation fall along one hyperbola; samples in the transition zone fall above it. Log samples are shown as small dots.
Each model at the current Swe. Hover to compare.
A synthetic sand with a transition zone at the base. Load your own LAS 2.0 or CSV with total porosity, Vsh and Sw curves; it stays in your browser. Click a depth to send it to the calculator.
Sample data (synthetic): 03_permeability_phit_vsh_sw.las (PHIT, VSH, SWT) 03_permeability_core_paste.txt (paste into Core calibration)
k in mD; φ and Sw as fractions. The effective column is the recommended one; the total column shows the bias from using total-system values in shaly sand.
Paste core samples as φt, Vsh, Sw, k_core (mD), one per line. Each is converted with the current φsh. The tool fits a multiplier for each model and a general form k = a·φeb/Swec.